Centrifuge Laboratory Introduction
 

The Centrifuge Laboratory is located at R314 and currently houses several models of high-speed and ultra-high-speed centrifuges, along with compatible rotors.
For safety reasons, only registered users are allowed to access the centrifuge room with an ID card.

 

※Rotor Calculation rpm/g
    Beckmancoulter 
    Hitachi

 
離心機室 離心機室
 
Centrifuge Laboratory Equipment Contact: Dia-Nan Lin   Tel-9527    
 

Ultra-high-speed

Hitachi

himac CP 100α

Beckman

Optima L-100K

Thermo

WX Ultera 80

Microscale- Ultra-high-speed

Beckman

Optima MAX-XP

High-Speed

Beckman

Avanti J-26XP

Hitachi

CR22GII

Thermo

LyNx6000

Benchtop

eppendorf

Centrifuges5804R

Beckman

Allegra X-15

Cytospin

Thermo

Shandon Cytospin4

 

Rotor

Brand

Max.(rpm)

swing-bucket

volume (ml)

P90NT

Hitachi

72K

5mlx8

RP83T

Hitachi

66K

12mlx8

RP83VT

Hitachi

66K

5mlx8

P70AT

Hitachi

65K

40mlx8

P45AT

Hitachi

36K

94mlx6

RPS40T

Hitachi

32K

v

13mlx6

SRP28SA

Hitachi

22K

v

40mlx6

RPR 20-2(Rotor7)

Hitachi

16K

50mlx8

RPS18-3(Rotor9)

Hitachi

18K

11mlx16

R10A3(Rotor13)

Hitachi

10K

500mlx6

 

Rotor

Brand

Max.(rpm)

swing-bucket

volume (ml)

70Ti

Beckman

64K

39mlx8

TY65

Beckman

52K

13.5mlx8

SW55Ti

Beckman

44K

v

5mlx6

Type55.2Ti

Beckman

44K

39mlx10

SW41

Beckman

33K

v

13.2mlx6

SW28

Beckman

22K

v

38.5mlx6

JA17

Beckman

14K

50mlx14

JA14

Beckman

11K

250mlx6

JLA-8.1000

Beckman

8K

1Lx6

 

Rotor

Brand

Max.(rpm)

swing-bucket

volume (ml)

TFT80

Thermo

80K

4mlx8

70V6

Thermo

70K

5mlx8

65V13

Thermo

65K

13.5mlx6

AH650

Thermo

50K

v

50mlx8

AH629

Thermo

29K

v

20mlx6 / 7mlx6

F-14

Thermo

14k

250mlx6

F-9

Thermo

9K

 

1000mlx6

A27

Thermo

27K

 

50mlx8

 

Rotor TLA-55

Beckman

55K

 

1.5mlx12

Rotor TLA-120.2

Beckman

120K

 

2mlx10

 
 
Centrifuge Laboratory Rules Contact: Dia-Nan Lin    Tel-9527   
   

1

These rules have been established to maintain the cleanliness of the centrifuge room and to ensure the efficiency and safety of centrifuge operation.

2

The centrifuge room is regulated by an access control system, only registered users are permitted to access the centrifuge room with their ID card.

3

Please close the centrifuge chamber while precooling.

4

We provide a refrigerator that is specific for rotor pre-cooling purposes at the Centrifuge Room. All rotor usages should be properly registered and logged.

5

The rotor must be BALANCED before running. Please ensure that the sample buckets positioned opposite each other in the rotor are of equal weights.

6

Tubes must be at least 90% full.

7

If users are more than 15 minutes late for their appointment, the registration will be deemed cancelled.

8

Do not leave the centrifuge until the full operating speed is achieved. If any abnormality is detected, please stop immediately and notify the manager (Rm401-5).

9

The centrifuge and rotor should be cleaned and properly stored after use. IT IS STRICTLY PROHIBITED TO BRING ROTORS OUT OF THE CENTRIFUGE ROOM.

10

ALL activity on the instruments MUST be logged, including user name, laboratory number, rotor type, speed and time.

11

Be sure that all equipment and work areas are carefully cleaned; EVERYTHING you may have brought into the lab, such as gloves, tubes, tips, samples, papers and bottles should be cleared away.

12

Anyone who violates the above regulations will have their name publically displayed and their PI will be informed of the violation.  

 

 
 
 